Hydraulic test benches
Endurance bench for mechanical cartridges

Endurance test bench for mechanical cartridges for mixing valves

Reference : LifeCartM
Areas of application :
Request a quote

Technical description

Main functions

The LifeCartM is an endurance test bench to verify the life, performance and hydraulic characteristics of mechanical cartridges for mixing valves.

Tests are performed to meet standards such as EN 817 and NF 077

 

  • Fidelity measurement, sensitivity, flow determination, etc.
  • Leakage and static pressure tests at 16 or 25 bar
  • Temperature adjustment with torque measurement
  • Flow rate adjustment with force measurement
  • Temperature and supply pressure measurement and monitoring
  • Endurance cycles
  • Automatic report generation

 

 

Operating mode

 

The equipment is a test bench equipped with several modules (from 2 to 6), designed to carry out performance and endurance tests of mechanical cartridges of mixing valves.

Each cartridge under test is mounted in a specific tool, connected to a hot and cold water supply and a piped mixed water outlet. The cartridge control lever is automatically operated by 2 actuators (1 rotary and 1 linear), capable of performing movements with position, speed and torque/force control. In addition, each module is equipped with a static pressure generator, allowing leakage and mechanical resistance tests to be carried out at pressures of up to 16 bar or 25 bar.

The bench is connected to two hot and cold water inlets. The temperature generation is done outside the bench. The hot and cold water supply pressures are provided either directly from the mains supply to the bench or by an external pressure generator (optional).

The software performs all performance and endurance tests by simple programming.

 

 

Hot and cold flow / test module
0-10 l/min
Pressure measurement
+/- 0,05 bar
Mixed water flow measurements
+/- 0,2 l/min
Maximum static test pressure
16 bars or optional 25 bars
Hot and cold supply pressure
0-10 bar
Hot and cold dynamic pressure control
0,1-8 bar
Hot and cold static pressure control (with pumps)
0,1- 10 bar
Accuracy of pressure regulation with pumps
<0,1 bar
Permissible temperature range of water supplies
10-85°C
Hot, cold and mixed water temperature measurements
+/- 0,5°C

 

Dimensions of a post

LifeCartM2 LifeCartM4 LifeCartM6

Width
1 760 mm 2 080 mm 2 400 mm

Depth
1 300 mm 1 300 mm 1 300 mm

Height
1 400 mm 1 400 mm 1 400 mm

Weight
200 kg 250 kg 300 kg

 

Benefits

  • Independent or synchronised testing
  • Standards-compliant testing
  • Flexibility